印刷用画面 友人に紹介する

Salifert Nitrate Test Kit No3 :: レビュー

価格243.27 krexcl. TAX
Sale227.00 krexcl. TAX
割り引き16.26 kr (7%)
リワード クレジット1.11 kr
数量
重量0.01 kg
No3 Tester
itrate Profi-Test
  • When there are insufficient areas of a tank which are deprived of oxygen (anaerobic zones) or denitrification is not taking place properly, nitrate will build up. This can also happen in an aquarium where the biological loading on the system is causing an imbalance e.g. if there is excessive livestock for the aquarium volume or over feeding is occurring.
  • The build up of nitrate can result in unwanted algae growth and the slowing down of coral growth.
  • The nitrate concentration in a reef aquarium should be lower than 1 mg/L, although fish only aquariums would usually have a higher concentration.
  • Just as with nitrite, many nitrate test kits are prone to amine interference which can make the levels of nitrate appear much lower than they actually are.
  • The Salifert test kit does not suffer from such interference and gives accurate and quick results with a total testing time of less than 3 minutes.
  • The test kit’s range goes from a very low to a very high nitrate concentration (approx. 0.2 - 100 mg/L as total nitrate).
  • Sufficient for 50 tests.
This test offers two ranges:
Low range: 0.2 - 10 mg/L (ppm) as nitrate.
Medium range: 2 - 100 mg/L (ppm) as nitrate.

Clean test vial and scoop after use. Store this kit in a dry place.

Warning!

KEEP OUT OF REACH OF CHILDREN.
 

Specifications 

Low range: 0.2 - 10 mg/L (ppm) as nitrate.
Medium range: 2 - 100 mg/L (ppm) as nitrate.

Procedure for both ranges:

  1. Fill test vial with 1mL of water.
  2. Add 1 level scoop of NO3-1 powder (compress this powder against the inner side of the powder container).
  3. Add 1 level scoop of NO3-2 powder and swirl gently (do NOT shake) for 30 seconds.
  4. Let it stand for 3 minutes.
  5. Color comparison:

    Medium Range:

    Place the test vial on the white part of the color chart and compare colors looking from the TOP. Use diffuse daylight when comparing colors.

    If the color corresponds to a value lower than 10mg/L nitrate then it might be better to compare colors as shown for the low range (see below).

    Low Range:

    If the medium range color comparison procedure gave a reading lower than 10mg/L then you can use the low range procedure. This will increase the accuracy.

    The color for the low range procedure has to be compared by looking through the SIDE of the test vial.

    The white part of the color chart has to be held firmly against the opposite side of the test vial. Use diffuse daylight when comparing colors.

    The color is, by looking through the side, amplified by approximately 10 fold. For this reason you have to divide the color chart values by 10. For example 2 will become 0.2 and 50 will become 5.
Filtered By 4 - よい 2 - あまりよくない 見つかりました: 1
評価
名前
Eメール
概要
Your Review
確認コード

Roberto on 12 12月 2015, 5:09 AM
Recomendo
Ótimo produto recomendo a todos
0 0
Comment Like Dislike
名前またはニックネーム
Eメール
詳しいコメント
確認コード
名前
Eメール
Your Question
確認コード

質問は見つかりませんでした。
最新の閲覧
Co2 Diffuser 9K Professional
価格85.26 krexcl. TAX
Sale59.71 krexcl. TAX
割り引き25.56 kr (30%)
Mini Co2 Diffuser
価格59.71 krexcl. TAX
Sale34.15 krexcl. TAX
割り引き25.56 kr (43%)
70W 20K HQI Bulb_RS7
価格170.53 krexcl. TAX
Sale128.00 krexcl. TAX
割り引き42.53 kr (25%)
250W 14K HQI Bulb E40 Metal Halide Lamp HQI
価格290.04 krexcl. TAX
Sale243.27 krexcl. TAX
割り引き46.77 kr (16%)
150W 7000K HQI Bulb RS7
価格170.53 krexcl. TAX
Sale65.67 krexcl. TAX
割り引き104.86 kr (61%)
3in1 Co2 Diffuser (S)
価格59.50 krexcl. TAX
Sale54.05 krexcl. TAX
割り引き5.46 kr (9%)